Qualification Outline

Date retreived
22/07/2026 12:19 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate IV in ESI - Power Systems Substations

Certificate IV in ESI - Power Systems Substations

Qualification
National Code:
UET40519
State Code:
BEV5
TGA Status:
Replaced
DTWD Status:
Replaced
National Endorsed, State Implementation and Classification
Field of Education
0313 - Electrical And Electronic Engineering And Technology
Original TGA Release Date
25/09/2019
Approved Date
04/12/2019
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
C
Nominal Hours
1206
Duration
3 Semesters
Current Release Number
1.00
Current Release Date
25/09/2019
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
1.00 25/09/2019 Current Replaced
Description

This qualification provides the skills and knowledge to work in power system substations in the electricity supply industry (ESI).
This qualification covers selecting, installing, setting up, testing, fault finding, repairing and maintaining electrical systems and equipment in buildings and premises. It also provides a career in installation and maintenance of substations, such as the maintenance of high voltage (HV) power system, including circuit breakers and transformers. It includes substation switching, inspection and diagnosing and rectifying faults. Options are available for skills to be obtained in high current direct current (d.c.) switchgear and equipment, installation of HV plant and equipment and/or the maintenance and commissioning of discrete protection and control systems.
It includes the Electrical Regulatory Authorities Council (ERAC) requirements for an ‘Electrician’s licence’. Competency development activities in this qualification are subject to regulations directly related to licencing.
The skills and knowledge described within the units in this qualification may require a licence or permit to practice in the workplace.
Additional and/or other conditions may also apply under state and territory legislative and regulatory licencing requirements which must be confirmed prior to commencing the qualification.

Schedule
Packaging Rules
A total of 1280 weighting points comprising:
- 1030 core weighting points listed below; plus
- 250 general elective weighting points from the general elective units listed below.

Choose a total of 250 weighting points elective units from the list below, of which between 0 and 50 weighting points can be taken from Group A; between 0 and 120 weighting points can be taken from Group B; and between 130 and 250 weighting points taken from Group C. You may select all your electives from this group.

Up to 50 weighting points of the general elective units Group A may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in UET Transmission, Distribution and Rail Sector Training Package Companion Volume Implementation Guide, if not listed weighting points will be 10 points.

Where imported units are selected, care must be taken to ensure all prerequisite units specified are complied with.
1. Core Units

All core units must be completed.

State Code National Code Title Hours Type
WC711 UEENEEK142A Apply environmentally and sustainable procedures in the energy sector 18 Unit of competency
S7307 UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace 18 Unit of competency
S7317 UEENEEG063A Arrange circuits, control and protection for general electrical installations 36 Unit of competency
OBH08 UETTDRSB22 Carry out power systems substation inspection 54 Unit of competency
S7326 UEENEEG109A Develop and connect electrical control circuits 72 Unit of competency
S7314 UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work 18 Unit of competency
S7308 UEENEEE102A Fabricate, assemble and dismantle utilities industry components 36 Unit of competency
S7310 UEENEEE105A Fix and secure electrotechnology equipment 18 Unit of competency
OBH52 UETTDRIS63 Implement & monitor power system environmental & sustainable energy management policies & procedures 27 Unit of competency
OBH53 UETTDRIS62 Implement and monitor the power system organisational WHS/OHS policies, procedures and programs 27 Unit of competency
OBH07 UETTDRSB23 Install and maintain substation direct current systems 27 Unit of competency
S8321 UEENEEG104A Install appliances, switchgear and associated accessories for low voltage electrical installations 18 Unit of competency
S7320 UEENEEG103A Install low voltage wiring and accessories 18 Unit of competency
S7324 UEENEEG107A Select wiring systems and cables for low voltage general electrical installations 54 Unit of competency
S7309 UEENEEE104A Solve problems in d.c. circuits 72 Unit of competency
S7318 UEENEEG101A Solve problems in electromagnetic devices and related circuits 54 Unit of competency
S7319 UEENEEG102A Solve problems in low voltage a.c. circuits 72 Unit of competency
S7316 UEENEEG033A Solve problems in single and three phase low voltage electrical apparatus and circuits 54 Unit of competency
S7315 UEENEEG006A Solve problems in single and three phase low voltage machines 72 Unit of competency
S7323 UEENEEG106A Terminate cables, cords and accessories for low voltage circuits 36 Unit of competency
S7325 UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits 36 Unit of competency
S7311 UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications 36 Unit of competency
S7322 UEENEEG105A Verify compliance and functionality of low voltage general electrical installations 36 Unit of competency
OBH85 UETTDREL16 Working safely near live electrical apparatus 18 Unit of competency
2. Group A: Imported and Common Elective Units

Between 0 and 50 weighting points may be chosen from Group A.
Please refer to the packaging rules for the full details of available options.

State Code National Code Title Hours Type
AUK47 BSBMGT403 Implement continuous improvement 50 Unit of competency
AUI61 BSBMGT402 Implement operational plan 50 Unit of competency
AUI60 BSBINM401 Implement workplace information system 40 Unit of competency
AUM06 BSBLDR402 Lead effective workplace relationships 40 Unit of competency
AUI57 BSBLDR403 Lead team effectiveness 40 Unit of competency
3. Group B: Qualification Elective Units

Between 0 and 120 weighting points may be chosen from Group B.
Please refer to the packaging rules for the full details of available options.

State Code National Code Title Hours Type
OBG98 UETTDRSB33 Install high voltage plant and equipment 45 Unit of competency
OBH02 UETTDRSB29 Maintain capacitor bank equipment for voltage regulation 36 Unit of competency
OBG92 UETTDRSB39 Perform power system substation switching operation to a given schedule 45 Unit of competency
OBH68 UETTDRIS47 Sample, test, filter and reinstate insulating oil 36 Unit of competency
OBH47 UETTDRIS67 Solve problems in energy supply network equipment 72 Unit of competency
OBH46 UETTDRIS68 Solve problems in energy supply network protection equipment and systems 36 Unit of competency
4. Group C: Qualification Elective Units

Between 130 and 250 weighting points taken from Group C.
Please refer to the packaging rules for the full details of available options.

State Code National Code Title Hours Type
OBG97 UETTDRSB34 Carry out surveys using thermovision techniques 27 Unit of competency
OBG95 UETTDRSB36 Commission discrete control and protection systems 27 Unit of competency
OBG93 UETTDRSB38 Commission power system distribution field devices 27 Unit of competency
OBH09 UETTDRSB21 Diagnose and rectify faults in substation environment 36 Unit of competency
OBH04 UETTDRSB26 Install high current d.c. equipment and switchgear 36 Unit of competency
OBG96 UETTDRSB35 Maintain discrete control and protection systems 72 Unit of competency
OBH03 UETTDRSB27 Maintain high current d.c. equipment and switchgear 36 Unit of competency
OBH05 UETTDRSB25 Maintain high voltage power and instrument transformers 72 Unit of competency
OBH06 UETTDRSB24 Maintain high voltage power system circuit breakers 54 Unit of competency
OBH01 UETTDRSB30 Maintain high voltage power system static VAR compensators (SVC) 27 Unit of competency
OBH00 UETTDRSB31 Maintain high voltage power system synchronous condensers 45 Unit of competency
OBG94 UETTDRSB37 Maintain power system distribution field devices 72 Unit of competency
OBG99 UETTDRSB32 Maintain power transformer on load tap changers (OLTC) 72 Unit of competency
Replaces
State Code National Code Title Type
J168 UET40512 Certificate IV in ESI - Power Systems Substations Qualification
Replaced By
State Code National Code Title Type
BHB2 UET40521 Certificate IV in ESI - Power Systems Substations Qualification
No information
Entry Requirements

There are no entry requirements for this qualification

Traineeships and Apprenticeships
No information