Qualification Outline

Date retreived
22/07/2026 5:17 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate IV in Large Scale Wind Generation - Electrical

Certificate IV in Large Scale Wind Generation - Electrical

Qualification
National Code:
UEP40612
State Code:
J529
TGA Status:
Replaced
DTWD Status:
Replaced
National Endorsed, State Implementation and Classification
Field of Education
0313 - Electrical And Electronic Engineering And Technology
Original TGA Release Date
07/09/2013
Approved Date
13/06/2013
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
C
Nominal Hours
1152
Duration
2 Semesters
Current Release Number
2.00
Current Release Date
07/09/2013
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
2.00 07/09/2013 Current Approved
Description

Scope
This qualification provides competencies to operate, test, fault find, alter, repair electrical equipment and systems associated with large scale wind power generation. It includes the requirements for an ‘Electrical Fitter licence’.

Schedule
Packaging Rules
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- Twenty one (21) core units
- A combination of elective units to achieve a total weighting of 380 points:
- A maximum of 60 weighting points may be chosen from Group A Imported and Common Elective Units
- A maximum of 120 weighting points may be chosen from Group B Elective Units.
- A minimum of 260 to a maximum of 380 weighting points may be chosen from Group C Elective Units.

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
1. Core Units

All twenty one (21) units must be completed.

State Code National Code Title Hours Type
S7307 UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace 18 Unit of competency
S7317 UEENEEG063A Arrange circuits, control and protection for general electrical installations 36 Unit of competency
WG181 UEPMNT202A Carry out routine work activities in an ESI large scale wind generation environment 18 Unit of competency
WC530 UEENEEG199A Conduct compliance and functional verification of electrical apparatus and existing circuits 36 Unit of competency
S7326 UEENEEG109A Develop and connect electrical control circuits 72 Unit of competency
S7314 UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work 18 Unit of competency
S7308 UEENEEE102A Fabricate, assemble and dismantle utilities industry components 36 Unit of competency
S7310 UEENEEE105A Fix and secure electrotechnology equipment 18 Unit of competency
WC714 UEENEEK145A Implement and monitor energy sector environmental and sustainable policies and procedures 18 Unit of competency
WC423 UEENEEE117A Implement and monitor energy sector OHS policies and procedures 18 Unit of competency
WG171 UEPMNT371A Maintain large scale wind turbine generators 54 Unit of competency
W7839 UEENEEE038B Participate in development and follow a personal competency development plan 18 Unit of competency
S7309 UEENEEE104A Solve problems in d.c. circuits 72 Unit of competency
S7318 UEENEEG101A Solve problems in electromagnetic devices and related circuits 54 Unit of competency
S7319 UEENEEG102A Solve problems in low voltage a.c. circuits 72 Unit of competency
S7316 UEENEEG033A Solve problems in single and three phase low voltage electrical apparatus and circuits 54 Unit of competency
S7315 UEENEEG006A Solve problems in single and three phase low voltage machines 72 Unit of competency
S7323 UEENEEG106A Terminate cables, cords and accessories for low voltage circuits 36 Unit of competency
S7325 UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits 36 Unit of competency
S7311 UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications 36 Unit of competency
WC453 UEENEEE185A Write work activity reports 18 Unit of competency
2. Group A Imported and Common Elective Units

A maximum of 60 weighting points may be chosen from Group A.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
W7811 UEENEEE009B Comply with scheduled and preventative maintenance program processes 18 Unit of competency
W7740 UEENEEC010B Deliver a service to customers 18 Unit of competency
W7731 UEENEEC001B Maintain documentation 18 Unit of competency
WC385 UEENEED101A Use computer applications relevant to a workplace 18 Unit of competency
3. Group B Elective Units

A maximum of 120 weighting points may be chosen from Group B.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
WC711 UEENEEK142A Apply environmentally and sustainable procedures in the energy sector 18 Unit of competency
WC632 UEENEEI116A Assemble, enter and verify operating instructions in microprocessor equipped devices 18 Unit of competency
WC473 UEENEEG111A Carry out basic repairs to electrical components and equipment 36 Unit of competency
WC501 UEENEEG157A Conduct electrical tests on LV electrical machines 36 Unit of competency
WC503 UEENEEG159A Conduct mechanical tests on electrical machines and components 36 Unit of competency
WE326 UEPOPS301B Conduct single energy source isolation procedures for permit to work 36 Unit of competency
WC666 UEENEEI150A Develop, enter and verify discrete control programs for programmable controllers 54 Unit of competency
WC475 UEENEEG116A Diagnose and rectify faults in traction lift systems 72 Unit of competency
WC472 UEENEEG110A Find and repair faults in LV d.c. electrical apparatus and circuits 54 Unit of competency
WC458 UEENEEF102A Install and maintain cabling for multiple access to telecommunication services 108 Unit of competency
WC460 UEENEEF104A Install and modify performance data communication copper cabling 36 Unit of competency
WG170 UEPMNT370A Maintain and monitor wind farm civil assets 36 Unit of competency
WC508 UEENEEG165A Maintain and service traction lifts systems and equipment 36 Unit of competency
WG169 UEPMNT369A Monitor climatic conditions for renewable electricity generation 36 Unit of competency
WE370 UEPOPS349B Operate Local H.V. switchgear 36 Unit of competency
WC487 UEENEEG129A Overhaul and repair major switchgear and controlgear 54 Unit of competency
WD670 UETTDRIS44A Perform HV field switching operation to a given schedule 45 Unit of competency
WC507 UEENEEG164A Repair and maintain mechanical components of electrical machines 36 Unit of competency
WC532 UEENEEH102A Repairs basic electronic apparatus faults by replacement of components 36 Unit of competency
WC464 UEENEEF108A Select and arrange equipment for wireless communication networks 36 Unit of competency
WC463 UEENEEF107A Set up and configure the wireless capabilities of communications and data storage devices 36 Unit of competency
WC467 UEENEEF111A Test, report and rectify faults in data and voice installations 36 Unit of competency
WC541 UEENEEH111A Troubleshoot single phase input d.c. power supplies 36 Unit of competency
WC388 UEENEED104A Use engineering applications software on personal computers 36 Unit of competency
WC618 UEENEEI101A Use instrumentation drawings, specification, standards and equipment manuals 36 Unit of competency
WD654 UETTDREL16A Working safely near live electrical apparatus 18 Unit of competency
4. Group C Elective Units

A minimum of 260 to a maximum of 380 weighting points may be chosen from Group C.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
WE388 UEPOPS402B Conduct multiple energy source isolation procedures for permit to work 36 Unit of competency
WE407 UEPOPS424B Coordinate local H.V. networks 27 Unit of competency
WG176 UEPMNT446A Coordinate maintenance on a wind farm 54 Unit of competency
WG175 UEPMNT445A Diagnose and repair faults in large scale wind turbine generators 54 Unit of competency
WG178 UEPMNT448A Diagnose and repair faults in wind turbine generator control systems 54 Unit of competency
WG177 UEPMNT447A Diagnose and repair faults in wind turbine generator electrical systems 54 Unit of competency
WG179 UEPMNT449A Diagnose and repair mechanical systems faults in wind turbine generators 54 Unit of competency
WG173 UEPMNT443A Maintain wind turbine generator control systems 54 Unit of competency
WG172 UEPMNT442A Maintain wind turbine generator electrical systems 54 Unit of competency
WG174 UEPMNT444A Maintain wind turbine generator mechanical systems 54 Unit of competency
WE432 UEPOPS456A Perform switching to a switching program 27 Unit of competency
WG180 UEPMNT450A Test and commission wind turbine generators 54 Unit of competency
Replaced By
State Code National Code Title Type
BEB5 UEP40618 Certificate IV in Large Scale Wind Generation - Electrical Qualification
No information
Entry Requirements

Not applicable.

Traineeships and Apprenticeships
No information